Fixing distances and heights of Rockpanel Lines²
In the tables below you find an overview of the maximum building height for fixing Rockpanel Lines² with the Rockpanel clip or Rockpanel ring shank nail on a wooden subconstruction with a 2-field span.
General information used as basis for the calculation of the fixing distances/heights, can be found in the general fixing guidelines & requirements.
If the table doesn't show any value for the maximum building height or the building is located in a specific area, please consult Rockpanel for a specific advice.
Rockpanel Lines² 8
Maximum building heght Lines² 8 mm, fixed with a single Rockpanel clip
| | | Lines² 8 XL | Lines² 8 S |
| Wind speed | Span c.t.c. | Zone B | Zone A | Zone B | Zone A |
| 22 m/s | 500 mm | 30 m* | - | 30 m* | 30 m* |
| 400 mm | 30 m* | 7 m | 30 m* | 30 m* |
| 23 m/s | 500 mm | 20 m* | - | 30 m* | 20 m |
| 400 mm | 30 m* | 5 m | 30 m* | 30 m* |
| 24 m/s | 500 mm | 15 m | - | 30 m* | 20 m |
| 400 mm | 30 m* | - | 30 m* | 30 m* |
| 25 m/s | 500 mm | 15 m | - | 30 m* | 15 m |
| 400 mm | 30 m | - | 30 m* | 30 m |
| 26 m/s | 500 mm | 10 m | - | 30 m* | 10 m |
| 400 mm | 20 m | - | 30 m* | 20 m |
Maximum building heght Lines² 8 mm fixed with a double Rockpanel clip
| | Lines² 8 XL | Lines² 8 S |
| Wind speed | Span c.t.c. | Zone B | Zone A | Zone B | Zone A |
| 22 m/s | 500 mm | 30 m* | 30 m* | 30 m* | 30 m* |
| 400 mm | 30 m* | 30 m* | 30 m* | 30 m* |
| 23 m/s | 500 mm | 30 m* | 30 m* | 30 m* | 30 m* |
| 400 mm | 30 m* | 30 m* | 30 m* | 30 m* |
| 24 m/s | 500 mm | 30 m* | 20 m | 30 m* | 30 m* |
| 400 mm | 30 m* | 30 m* | 30 m* | 30 m* |
| 25 m/s | 500 mm | 30 m* | 20 m | 30 m* | 30 m* |
| 400 mm | 30 m* | 30 m | 30 m* | 30 m* |
| 26 m/s | 500 mm | 30 m* | 15 m | 30 m* | 30 m* |
| 400 mm | 30 m* | 30 m | 30 m* | 30 m* |
Rockpanel Lines² 10
Maximum building heght Lines² 10 mm fixed with a single Rockpanel ring shank nail 2,1/2,3 x 27
| | | Lines² 10 XL | Lines² 10 S |
| Wind speed | Span c.t.c. | Zone B | Zone A | Zone B | Zone A |
| 22 m/s | 600 mm | 5 m | - | 30 m* | 15 m |
| 500 mm | 7 m | 5 m | 30 m* | 30 m |
| 23 m/s | 600 mm | - | - | 20 m | 10 m |
| 500 mm | 7 m | - | 30 m* | 20 m |
| 24 m/s | 600 mm | - | - | 15 m | 7 |
| 500 mm | 5 m | - | 30 m* | 15 m |
| 25 m/s | 600 mm | - | - | 15 m | 7 m |
| 500 mm | 5 m | - | 20 m | 30 m |
| 26 m/s | 600 mm | - | - | 10 m | 5 m |
| 500 mm | - | - | 20 m | 10 m |
Maximum building heght Lines² 10 mm fixed with a double Rockpanel ring shank nail 2,1/2,3 x 27
| | Lines² 10 XL | Lines² 10 S |
| Wind speed | Span c.t.c. | Zone B | Zone A | Zone B | Zone A |
| 22 m/s | 600 mm | 30 m* | 15 m | 30 m* | 30 m* |
| 500 mm | 30 m* | 30 m | 30 m* | 30 m* |
| 23 m/s | 600 mm | 30 m | 15 m | 30 m* | 30 m* |
| 500 mm | 30 m* | 20 m | 30 m* | 30 m* |
| 24 m/s | 600 mm | 20 m | 10 m | 30 m* | 30 m* |
| 500 mm | 30 m* | 15 m | 30 m* | 30 m* |
| 25 m/s | 600 mm | 15 m | 7 m | 30 m* | 30 m* |
| 500 mm | 30 m | 15 m | 30 m* | 30 m* |
| 26 m/s | 600 mm | 15 m | 7 m | 30 m* | 30 m* |
| 500 mm | 20 m | 10 m | 30 m* | 30 m* |